Sample Report

January 11, 2005
Mr. John Homebuyer
111 Old House Road
Middletown, New York 11777
Inspection Site: 112 New House Lane, Pleasantville, New York
Inspection
Date: October 18, 2004
Congratulations ! You are considering the purchase
of a new home!
Thank you for selecting Long Island Home Inspection Consultants to
perform your building inspection for you.
We invite you to checkout our website www.longislandinspection.com .
Our website is packed with great information about the various components
that make up a house or building.
If you attended the inspection, our inspector has already provided you
with a verbal report and discussion of his findings. We would like to
continue our relationship with you, even after you have closed on your
new property. If you haven't done so already, please tell us your email
address so we can periodically remind you of important maintenance advice
to keep your home/office in great condition year round and prolong the
life of all components.
The following report is designed to highlight significant defects
uncovered during the inspection and provides maintenance suggestions
to protect and prolong the life of the area discussed.
The inspection has been performed in accordance with A merican
Society of Home Inspectors' (A.S.H.I.) standards.
It is intended only as a general guide to help the client make
his or her own evaluation of the overall condition of the home
and is not intended to reflect the value of the premises, nor make
any representation as to the advisability of purchase. The report
expresses the personal opinions of the experienced inspector, based
upon his visual impressions of the conditions that existed at the
time of inspection only. The inspection and report are not intended
to be technically exhaustive or to imply that every component was
inspected or that every possible defect was discovered. No disassembly
of equipment, opening of walls, moving of furniture, appliances
or stored items, or excavation is performed. All components and
conditions, which by nature of their location are concealed, camouflaged
or difficult to inspect are excluded from the report. We can provide
an excellent overview of the property, but may not find every defect;
or uncover every possible risk, whether visible or not.
The inspection report should not be construed as a compliance inspection
of any governmental or non-governmental codes or regulations. The report
is not intended to be a warranty or guarantee of the present or future
adequacy or performance of the structure (we can not predict the future),
its systems or their component parts. This report does not constitute
any expressed or implied warranty of merchantability or fitness for
use regarding the condition of the property and it should not be relied
upon as such. Any opinions regarding adequacy, capacity or expected
life of components are general estimates based on information about
similar components and occasional wide variations are to be expected
between such estimates and actual experience
We certify that our inspectors have no interest, present or contemplated,
in this property or its improvements. To the best of our knowledge and
belief, all statements and information in this report are true and correct.

TABLE OF CONTENTS
CONGRATULATIONS!
Welcome ....... 1-2
TABLE OF CONTENTS ...............................
3
OFFICE USE ONLY: PAID BILL ............................... 4
OFFICE
USE ONLY: BILL ............................... 5
EXTERIOR ............................... 6-8
PHOTOS .......................... 8A
TERMITE REPORT ............................... 9
INTERIOR
Structure and Foundation ...............................
10-11
Attic
or Crawl Spaces ............................... 12
Plumbing/Heating/Electrical
Systems ............................... 13-17
Rooms ...............................
18
GENERAL NOTES ...............................
19-21
SUMMARY ...............................
22

January 11, 2005
Mr. John Homebuyer
111 Old House Road
Middletown, New York 11777
Inspection Site: 112 New House Lane, Pleasantville, New York
Inspection
Date: October 18, 2004
Inspection Fee: $ _________
Total Amount Paid: $
PAID IN FULL…THANK YOU!
EXTERIOR |
| ITEM |
MATERIAL |
RECOMMENDATIONS |
| Street Sidewalk |
Concrete |
Repair lifted and cracked sections of sidewalk
to eliminate tripping hazard. Cut tree root to prevent future
maintenance of this type. |
| Driveway |
Concrete |
Repair cracks in driveway surface as needed . |
| Front Walkway |
Concrete/Slate |
Point worn mortar joints on front walkway as needed. |
| Front Stoop |
Brick |
Repoint mortar joints on front stoop as needed. |
| Entry Doors |
Wood |
Replace all exterior door locks as a security
measure. Replace/repair hardware as necessary on front door.
Trim rear door to operate properly. Adjust doorknob hardware
and strike plates so that doors will latch properly. |
| Railings |
Wrought Iron |
This area was found to be in serviceable/satisfactory
condition at time of inspection. |
| Chimney |
Stucco |
Install chimney cap to prevent water, or animal entry. Contact
chimney sweep to clean chimney on an annual basis. At time of
cleaning the interior of the flue liner, which was not visible
at time of inspection, should be inspected. |
| Roof |
Asphalt Shingle |
The estimated age of the roof is under 5 years.
Transfer guarantee on this recently installed roof, if applicable.
Periodic inspection of all roofed and flashed areas is advisable
as a preventative maintenance. |
| Flashing |
Copper/Aluminum |
Paint rusted metal flashing with rust inhibitor
and monitor for further rusting, which would necessitate
replacement. Wall-to-roof flashing on east side of house is installed
improperly and may allow leakage during heavy rain. Ideally,
it should be installed beneath the shingles. |
| Gutters/Leaders |
Aluminum |
Direct all leaders away from house for positive
drainage. Proper management of gutter/leader system is important
for preventing soil erosion and possible damage to foundation/structure
as well as for helping to keep the basement/crawl area dry. At
least twice a year gutters, leaders, and downspouts should be
cleaned and checked for proper alignment and connection. As part
of normal home ownership, check system during rain for leaks
and proper drainage. |
| Exterior Walls |
Frame |
The quantity and type of insulation installed
in exterior wall cavities could not be determined due to enclosed
nature of walls. Obtain owner representation as to the type of
insulation used to determine if any health hazards or deficiencies
exist. |
Siding |
Stucco/Cedar Shingle/
Clapboard |
This house has been sided with an
exterior insulation and finish system using synthetic stucco
as the finish material. Proper installation and maintenance
techniques of stucco finish are critical. Flashing and detailing
at windows, doors, and wall-to-roof sections are the primary
concerns. Improper installation can lead to water entering
and collecting within the wall structure causing rot from
the inside out. Patch cracks in stucco finish to prevent
water entry. There are signs that the finish-coat on the
stucco has not adhered properly. This may be able to be spot-repaired
or it may eventually be necessary to remove defective finish-coat
entirely and apply a new one. Portions of
stucco siding are installed without the benefit of a weep
screed at the bottoms of walls. A weep screed allows any
water that has accumulated within walls to drain out. The
absence of one may trap water, which can in turn lead to
damage to the interior of wall, as well as possible mold
growth, none of which can be visible unless the wall is opened
up. The patio on the east side can cause back-splash water
damage to wood shingle siding. Power wash siding to remove
dirt sediment and discoloration. |
Masonry |
Cement Block |
This area was found to be in serviceable/satisfactory
condition at time of inspection. |
Trim |
Wood |
Scrape and paint all wood trim. Replace
rotted trim where necessary. Rot was observed on wood window
frames and portions of other trim. |
Paint |
Waterbase |
Periodic repainting will be required
as part of normal homeowner maintenance. |
Caulk |
Silicone |
Maintain caulking around all windows
and window frames. Scrape off old caulking where needed. Recommend
using silicone caulk, which has longer life expectancy. |
| Storms / Screens |
Aluminum/
Thermopane/Screens |
Check for proper quantity of storm
and screen inserts prior to closing. |
| Sidewalk |
N/A |
Not Applicable |
| Side Stoop |
N/A |
Not Applicable |
| Window Wells |
Masonry |
Install window well covers on existing
window wells to help prevent water seepage and the accumulation
of debris. |
| Rear Walk |
Concrete |
Repair cracks in rear walkway as needed.
Repair uneven sections of rear walkway to eliminate tripping
hazard. |
| Rear Stoop |
Concrete |
This area was found to be in serviceable/satisfactory
condition at time of inspection. |
| Deck |
N/A |
Not Applicable |
| Grading |
Level |
Re-pitch soil away from foundation
to aid in positive drainage. Soil should slope away at 1 inch
per foot for 5 to 8 feet to help prevent seepage into basement.
Masonry areas in contact with house should be sealed periodically
with caulking or mortar to help prevent seepage. When these areas
are resurfaced, they should be pitched away from the foundation
to better aid in positive run-off. |
| Landscape |
Trees |
Prune shrubs and trees presently in
contact and/or overhanging structure. Trees that are close to
the building can cause damage to the foundation and other parts
of structure. Removal of said trees is recommended. Maintain
a 6 to 12 inch gap between shrubbery and side of dwelling. |
| Patio |
Brick/Concrete/
Slate |
The patio on the east side of the
house is in poor condition. Its reconstruction is necessary at
this time. Removal is also an option. |
| Pool |
N/A |
Not Applicable |
| Fences |
Stockade |
V erify ownership of perimeter fencing
and maintain where applicable. |
| Retaining Walls |
N/A |
Not Applicable |
| Access Buildings |
N/A |
Not Applicable |
| Bulkhead |
N/A |
Not Applicable |
| Garage |
3 Car - Detached |
Portions of the garage were inaccessible
due to excessive storage. No representation as to conditions
that were inaccessible can be made. A careful re-inspection of
garage space is needed prior to closing when vacant to check
for any hidden damage, defect or insect infestation. Garage doors
will require repair or replacement due to damage. Lubrication
and replacing of missing door hardware is also needed. Rot and
other damage were also observed around the structure. |

January 11, 2005
Mr. John Homebuyer
111 Old House Road
Middletown, New York 11777
Inspection Site: 112 New House Lane, Pleasantville, New York
Inspection
Date: October 18, 2004 TERMITE INSPECTION REPORT
Based on careful visible inspection of accessible areas and on sounding
of accessible structural members, both termite activity and termite
damage were observed at time of inspection. Since a previous treatment
has been done we recommend to retreat affected areas only. (Exterminate
as per chemical manufacturer's recommendations and in accordance
with recognized practices and guidelines set forth by the “D.E.C.” Department
of Environmental Conservation and the “E.P.A.” Environmental Protection
Agency). If present owner has existing guarantee, transfer and
employ to rectify situation. Test b orings should be made on all
structural members and framing to check for latent damage. Institute
repairs as necessary. Annual termite inspections are recommended
as a preventative maintenance measure. We cannot represent the
absence or presence of termites and other wood destroying insects
or resulting damage within closed walls or sealed floors. Damage
was observed on window frame of garage, on main support girders
near stairs in basement, and mud shelter
tubes, which are indicative of activity, were observed in basement
bathroom. Replacement of sill plate with new pressure-treated
lumber was also observed in the basement bathroom, indicating prior
correction of previous damage. Drill marks were observed on both
stoops indicating prior treatment. The basement is partially finished.
Framing behind finished materials was not visible for inspection.
Since concrete block foundations are particularly vulnerable to
termite infestation, the need for regular termite inspections cannot
be understated. Obtain documentation of termite treatment history,
if any, from present homeowner.
Thank you.
Long Island Home Inspection Consultants
____________________________
Terence Kursawe
ID#C1811196
INTERIOR
STRUCTURE AND FOUNDATION |
| ITEMS |
DESCRIPTION |
RECOMMENDATIONS |
| Termites |
See Remark |
Based on careful visible inspection of accessible
areas and on sounding of accessible structural members,
both termite activity and termite damage were observed at time
of inspection. Since a previous treatment has been done we
recommend to retreat affected areas only. (Exterminate as per
chemical manufacturer's recommendations and in accordance with
recognized practices and guidelines set forth by the “D.E.C.” Department
of Environmental Conservation and the “E.P.A.” Environmental
Protection Agency). If present owner has existing guarantee,
transfer and employ to rectify situation. Test b orings
should be made on all structural members and framing to
check for latent damage. Institute repairs as necessary.
Annual termite inspections are recommended as a preventative
maintenance measure. We cannot represent the absence or
presence of termites and other wood destroying insects
or resulting damage within closed walls or sealed floors.
Damage was observed on window frame of garage, on main
support girders near stairs in basement, and mud shelter
tubes, which are indicative of activity, were observed
in basement bathroom. Replacement of sill
plate with new pressure-treated lumber was also observed
in the basement bathroom, indicating prior correction of
previous damage. Drill marks were observed on both stoops
indicating prior treatment. The basement is partially finished.
Framing behind finished materials was not visible for inspection.
Since concrete block foundations are particularly vulnerable
to termite infestation, the need for regular termite inspections
cannot be understated. Obtain documentation of termite
treatment history, if any, from present homeowner. |
| Other Pests |
None |
There were no visible signs of other insects at
time of inspection, however, periodically monitor structure for
carpenter ants, termites, and/or other pests during warmer months.
Contact a qualified pest control company if necessary. |
| 34.Dry Rot |
No Visible Signs |
Not Applicable |
| 35. Water Entry |
See Remark |
Spaces in the house that are below ground level
may be subject at any time to water infusion from the exterior.
While every effort is made to identify signs of past or present
water entry, it is generally not possible to guarantee an underground
area will remain dry, especially when finished walls conceal
the building foundation from view. There is evidence of seepage
in the basement area. Check Exterior Recommendations #1 through
#32 for possible remedies. If necessary, treat foundation walls
with waterproofing compound or contact qualified waterproofing
company. Efflorescence was observed on foundation walls in the
basement. Efflorescence is a white powdery residue, which indicates
that at some time, water has seeped through the basement walls.
The exterior cellar doors may be a source of water entry during
rain. Add waterproofing to doors if problem develops. The efficacy
of the floor drain in the basement could not be determined. The
water stains observed on the basement ceiling (the first floor
sub-floor) have resulted from interior water leakage from above.
While the stains did not appear to be active during the time
of inspection, ongoing monitoring is advised. |
|
|
|
| 36. Foundation |
Cement Block |
Due to the enclosed nature of the basement, portions
of the foundation, girder, and column system were not visible
for inspection. However, those areas that were observed appeared
to be satisfactory. Painted foundation walls may be hiding cracks
or other defects. Should cracking become apparent, contact a
foundation specialist for recommendations and repairs. Repair
cracks as necessary. |
| 37. Girders |
Wood |
Termite damaged main girder material should be
replaced in order to renew structural integrity. |
| 38. Columns |
Steel Lally |
When termite damaged materials are replaced, the
temporary jack posts can be removed. |
| 38A. Miscellaneous |
_ |
_ |
| ITEMS |
DESCRIPTION |
RECOMMENDATIONS |
| Insulation |
Fiberglass |
The average depth of insulation in the uppermost
attic area was approximately 3 to 4 inches. The average depth
of insulation observed in accessible knee-wall spaces was approximately
1 to 2 inches. Install layer of unfaced insulation throughout
attic floor areas to a total thickness of six inches minimum
(R-19). |
| Floor |
None |
Not Applicable |
| Ventilation |
Gable/Ridge |
Attic ridge ventilation is present. Wind-driven
rain and/or snow can sometimes enter the attic through this opening.
It depends on the quality of installation and product. Deficiencies
in this area are not always readily apparent during a visual
inspection. It is recommended to periodically check the attic
during or right after the above described weather conditions.
Open closed gable vent to allow for improved air ventilation
in attic area. |
| Water Leaks |
No Visible Signs |
Not Applicable |
| Access |
Hatch |
This area was found to be in serviceable/satisfactory
condition at time of inspection. |
| 43A. Electric |
N/A |
Not Applicable |
| 43B. Storage |
N/A |
Not Applicable |
| 43C. Misc. |
|
|
| ITEMS |
DESCRIPTION |
RECOMMENDATIONS |
| 44. Fixtures |
See Remark |
Recommend clearing all drain lines as a precautionary
measure. |
| |
Kitchen |
Plastic bags wrapped around drainpipe are a poor
attempt at a repair. A more permanent repair should be effected. |
| |
1 st Floor Bathroom |
The toilet was not working. The shower handle
was missing. Re-test shower fixture after replacement of handle. |
| |
2 nd Fl Kitchen |
Replace improper “S” trap with a proper trap installation. |
| |
2 nd Floor Bathroom |
The sink in this room was not hooked up and therefore,
could not be tested. |
| |
3 rd Floor Bathroom |
The tub faucet should be above the flood-rim of
the bathtub to eliminate cross-connection, which could lead to
bacterial contamination of tap water. The tub faucet was also
not working. The toilet was not functional. The sink drain was
clogged. Contact a qualified licensed plumber to review and repair
as necessary. |
| |
Hall Bathroom |
The toilet was not operational. |
| |
Basement Bathroom |
Hot water pressure at the sink was weak. |
| |
Laundry Sink |
The drain pipe from the sink is improperly sloped
and will not allow for proper drainage. The pipe
is also disconnected at the main house drain. |
| Drain Lines |
Galvanized/PVC |
Future replacement of galvanized water pipe can
be anticipated as galvanized piping has a tendency to either
rust through or close-up internally as a result of corrosion;
thereby, restricting water flow. PVC drain lines in this house
may be hazardous in the event of fire and are usually noisy during
operation. Avoid using harsh drain cleaners with PVC piping . |
| Waste Lines |
Cast Iron |
Waste piping in this house is original. They could
be prone to clogging and restricted flow because of internal
corrosion. Future repair or replacement may be required. |
| Supply Piping |
Copper/Galvanized |
Insulate exposed cold water piping to eliminate
condensation. Insulate hot water pipes to conserve energy. Comments
in #49A regarding galvanized piping apply here as well. Low water
pressure at a fixture will be a possible indication of the need
for galvanized supply pipe replacement. Dielectric fittings may
need to be installed at joints between copper and galvanized
steel pipes to prevent galvanic corrosion of pipes. |
| Plumbing Valves |
Brass |
Label plumbing valves for identification purposes.
Monitor encrusted valves for leakage, which would necessitate
replacement. |
| Water Supply |
Municipal |
The municipal water supply is located in the basement.
The incoming water line is made of copper. |
| Water Heater |
Tankless Coil/ STATE/40 Gallon/Oil |
The hot water heater was shut-down at time of
inspection and therefore not tested. It should be evaluated
by a qualified heating technician prior to closing. Extend relief
valve to within six inches of the floor for safety. There
are indications that the relief valve has purged. This indicates
a problem with the valve or with the water heater. Consult with
a qualified heating technician for further review. The average
lifespan of a water heater under normal conditions is between
5 and 10 years. It is possible that this unit may require replacement
within 5 years. Generally, water heaters do not need replacement
unless they leak. Check with owner for documentation on the installation
date of water heating equipment. Hot water for the dwelling is
currently provided by the tankless coil inside the steam boiler.
Limited hot water supply can be anticipated with this type unit
unless coupled to storage tank. Consider replacing unit with
separate, self-contained, fuel efficient hot water heater. Adjust
water temperature (temperature above 120 degrees may scald).
Temperature readings taken at faucets exceeded 200 degrees. The
piping arrangement between the tankless coil and the hot water
heater may not be optimum. Evaluation by a qualified heating
technician is also recommended. |
| Heating System |
RELIANCE/ Steam Boiler/1 Zone Proof |
Although this unit was operating at time of inspection,
due to age of unit, future replacement can be anticipated.
Renew seal in area where vent stack intersects chimney. A carbon
monoxide test was performed on this house and readings were elevated
in the flue at time of inspection. This is usually an indication
that the system requires cleaning and adjustment, but final determination
should be made by a qualified heating technician. Periodic testing
is recommended as a safety precaution. Scorch marks on the front
of the boiler can be attributed to past
flame roll-out. The piping arrangement on the boiler equalizer
is not optimum. The efficiency of the unit may be able to be
improved by a re-arrangement of the pipes. Relief vents at the
ends of the steam mains should be at the
end of the horizontal lengths of both mains and not on vertical
return piping. This will also improve the operation of the system.
It is recommended to place heating equipment under a service
contract to receive regularly scheduled maintenance. Have the
contract take effect a day or so before closing and arrange to
have a heating technician present during a final walk-through
to inspect and service equipment. Be sure to have an understanding
as to which equipment and services will be covered under
the contract. |
| Burner |
Oil |
Condition and quantity of buried oil tank on exterior
of house could not be determined at time of inspection. It is
strongly recommended to test tank and/or surrounding soil for
possible leaks. Recommend discontinuing use of existing tank
and installation of an above-ground storage tank to eliminate
potential environmental hazard. |
| Humidifier |
N/A |
Not Applicable |
| Heat Pipes |
Iron |
Insulate exposed heating pipes where none currently
exist, for maximum efficiency of system. Dielectric fittings
may need to be installed at joints between copper and iron pipes
to prevent galvanic corrosion of pipes. Consult with a qualified
heating technician for further review. Surface temperatures of
steam heating pipes can reach levels high enough to present a
risk of burn injury. It is recommended to install protective
installation around exposed steam pipes. Also, a significant
amount of heat is lost on uninsulated pipes. Insulating will
also greatly increase the efficiency of the heating system. Steam
pipes can be prone to leakage at joints and should be checked
periodically for the same. Some water stains on basement ceilings
appear to be caused by past leakage. |
| Cool/Heat Ducts |
N/A |
Not Applicable |
| Radiation |
Radiators |
When tested, no heat rose from the heaters located
from several of the heaters located throughout the house. Consult
with a qualified heating technician for further review. No permanent
heat source was observed in the kitchen. Heaters in the second
floor west bedroom were disconnected. Surface temperatures of
steam heating pipes can reach levels high enough to present a
risk of burn injury. It is recommended to install protective
installation around exposed steam pipes. Also, a significant
amount of heat is lost on uninsulated pipes. Insulating will
also greatly increase the efficiency of the heating system. Steam
pipes can be prone to leakage at joints and should be checked
periodically for the same. Water stains on basement ceiling appear
to be caused by past leakage. |
| Electric Service |
100 Amp, 120/240 Volt |
The main electric service panel is located in
the basement. Fuses are used in this dwelling for electrical
over-current protection. Many lenders will not underwrite
a house with fuses. It is recommended to replace fuse panels
with a single 150 or 200 Amp circuit breaker panel. There are
several unsafe wiring practices in use, which will need
to be addressed if the electrical service upgrade is not performed
immediately. Several wires have been tapped off of main
wire connections in panels. Sub-panel has
two fuses that are over-rated for the wire connected to them,
which is a fire hazard and that panel is not grounded either.
The panel also has sections of copper pipe installed
in place of cartridge fuses to defeat over-current protection,
which is also a fire hazard. Replace outlets that do not hold
plugs tightly. Loose outlets/switches should be securely tightened
to their receptacle boxes. Replace any missing outlet/switch
plates. Replace all two wire outlets with three wire grounded
outlets for added safety. The installation of a proper
ground wire may be required. Contact a qualified licensed electrician
to repair open ground outlets as needed. Correct hot/ground
reversed wiring at outlets on west kitchen wall. Install GFCI
(Ground Fault Circuit Interrupt) outlets in kitchen countertop
area, bathrooms, and exterior locations for safety. All GFCI
outlets should be properly grounded. Replace defective GFCI outlet
in first floor bathroom. Test all GFCI outlets monthly. |
| Electric Wiring |
Copper/Bx/Fuses |
|
| Central Air |
N/A |
Not Applicable |
| 63. Wall A/C Units |
N/A |
Not Applicable |
| Fireplace |
See Remark |
The fireplace in the living room has been walled-over
and could not be evaluated. |

INTERIOR
ROOMS |
| ITEMS |
RECOMMENDATIONS |
| Living Room |
Mold growth, which was observed in the living
room closet, is typically caused by repeated exposure to
excessive moisture/water. All building materials contaminated
by mold should be treated with a biocide and/or replaced if necessary,
after positive determination and correction of this exposure.
Wallpaper that has been painted over will be difficult to remove. |
| Side Sun Room |
Replace old wood casement window with energy-efficient
thermopane windows. |
| Dining Room |
See previous comment #65. |
| Kitchen |
The window on the west wall of this room displayed
evidence of a failed seal. Typically a window with a failed seal
will accumulate condensation between the panes. This means that
while the window will still function as a normal window, the
enhanced insulative properties of the glass are gone. The only
repair is replacement. It is possible that other currently satisfactory
windows that are the same age may experience seal failure in
the future. It should also be noted that when such a window has
condensation stains between the panels, it could never be cleaned.
Replace missing countertop tiles. |
| Rear Sun Room |
This area was found to be in serviceable/satisfactory
condition at time of inspection. See General Notes . |
| Bathroom |
Install electronic exhaust fan vented to exterior
to remove excessive moisture. |
| 2 nd Floor (3) Bedrooms |
The water stains on the southeast bedroom closet
and the second floor kitchen area ceiling do not appear to be
active during the time of inspection, however it is recommended
to monitor stained areas during and after heavy rain. Water damage
was observed on wood trim on the ceiling of the northeast bedroom.
It appears that this may have been caused by a flood on the third
floor. |
| 2 nd Floor Bathroom |
Replace glass tub/shower doors or enclosure with
safety glass or plexiglass for safety. Extensive repairwork has
been performed on the shower tiles. Internal wall damage may
be present. Vinyl floor tiles are not securely attached to the
floor. This may be related to flooding, which was described in
Comment #70. |
| 3 rd Floor (2) Bedrooms |
This area was found to be in serviceable/satisfactory
condition at time of inspection. See General Notes . |
| Bedroom Bathroom |
This area was found to be in serviceable/satisfactory
condition at time of inspection. See General Notes . |
| Hall Bathroom |
The fiberboard panel tub surround has deteriorated
and will require replacement. |

General Notes
- As this inspection was conducted during daylight hours,
the effectiveness of exterior lighting could not be determined.
Repair existing or add where necessary for safety.
- Condition of cesspool/septic system could not be determined
at time of inspection; however, anticipate maintaining, cleaning
and/or replacement.
- Sunken areas in backyard may in fact be collapsed
cesspool. Further determination of this would require investigative
work from a cesspool company.
- Water supply valves to the washing
machine should always be turned off when the washer is not in use.
Otherwise the washer hoses, which contain live water pressure,
could rupture at a most inopportune time, potentially causing significant
water damage.
- Clogged
dryer vents are a leading cause of home fires. Dryer vent should
be disassembled and cleared of accumulated lint upon occupancy and
periodically as part of normal maintenance. A clean dryer vent will
improve the efficiency of the dryer as well.
- The flooring in this
building consists of wood, tile, and carpet.
- The walls
and ceilings in this building are plaster, sheet rock, panel, stucco,
wood, fiberboard, tile, and suspended ceiling.
- The windows
are vinyl double hung thermopane, vinyl slider, and wood casement.
- Settled or sunken floor areas appeared to be related to age as
opposed to defect, however, this could not be accurately determined
at time of inspection. Since all floors and ceiling were closed,
same should be watched carefully for any indication or further movement,
which may necessitate extensive repairs.
- No determination can
be made as to the surface condition of any flooring that is covered
by finished materials.
- No
determination can be made as to surface condition of wood flooring
that is covered by carpeting.
- Clean or replace carpeting
throughout.
- No
representation can be made as to the condition of the wall surfaces
beneath the wood paneling. Use caution if removing wall covering
to avoid damaging underlying wall surfaces.
- Ceilings above
suspended ceiling should be checked for damage, looseness, defects,
etc., which may require repair.
- Ceilings above tile ceilings
should be checked for damage, looseness, defects, etc., which may
require repair.
- Stucco
that has been applied to walls and ceilings will be difficult to
maintain or remove.
- Trim doors throughout to operate properly.
Install missing doorstops to prevent damage to walls.
- Adjust
doorknob hardware and strike plates so that doors will latch properly.
- Maintain caulking around all interior and exterior seams of the
tub/shower area with bathroom silicone caulking to prevent possible
moisture penetration.
- Install a complete smoke detection system in
dwelling. Test and repair or replace any smoke detectors from previous
occupant. Install carbon monoxide detectors as well for additional
safety.
- A carbon
monoxide test was performed on this house and readings were slightly
elevated in flue at time of inspection. See Comment #54-55. Periodic
testing is recommended as a safety precaution.
- Obtain
Certificate of Occupancy on house including any needed permits.
- Due
to excessive storage and/or furnishings in some areas, it would be
advisable to recheck this house when it is vacant and all areas visible
and accessible.
- Adjust/lubricate
window hardware as necessary.
- Recommend replacement of
old windows with high quality thermopane units to reduce maintenance
and retard heat loss.
- Lead paint was widely used in houses
built prior to 1978 and is a known health hazard. Recommend having
this house tested for lead paint, and if present, abate as necessary.
- Molds affect individuals differently, and while most common molds
can be safely removed without the assistance of a professional, some
molds are toxic and the average homeowner should not attempt the
abatement of these types of mold. Laboratory testing would be necessary
to identify the different types of mold. Abatement of toxic mold,
which may require removal of building materials, is an expensive
process and should be done by qualified professionals. Contact this
office if mold testing is desirable.
- When
recommendations have been made for repairs and/or service, we suggest
you contact a qualified tradesperson prior to closing so actual costs
involved can be anticipated.
- All mechanical equipment should be maintained under contract and/or
on a regular basis as prescribed by manufacturer.
- There is
no representation made in this report as to the conclusion of environmental
analysis, if performed, such as air quality (radon or urea formaldehyde
levels, pollution or noxious gases); or the quality of water and/or
soil. A full spectrum of environmental testing is available and includes:
radon, water, electro magnetic fields, etc. With exception to those
mentioned as performed in this report, the remaining tests were not
performed.
- Recheck
this structure immediately prior to closing for things that may have
changed since the inspection or were inaccessible due to furnishings
and/or storage. All mechanical systems should be checked for malfunctions.
All windows and doors should be checked for proper operation. All
finished walls, floors, and ceilings should be checked for damage.
All plumbing fixtures should be checked for proper operation, etc.
- This inspection has been performed in accordance with American
Society of Home Inspectors (ASHI) standards. A copy of the ASHI standards
will be provided at the client's request.
SUMMARY
This house has been generally well constructed and maintained within
reason. Work is needed to put house into proper condition. Anticipate
ongoing maintenance as part of normal home ownership. |